Arkon Channelmag User Manual

Browse online or download User Manual for Unknown Arkon Channelmag. Arkon Channelmag User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 25
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
CHANNELMAG FLOWMETERS
FOR OPEN CHANNELS AND NON- FULL PIPES
RTM- Expolink s.r.o., Prikop 8, 60200 Brno, Czech Republic
Instruction Manual
Page view 0
1 2 3 4 5 6 ... 24 25

Summary of Contents

Page 1 - CHANNELMAG FLOWMETERS

CHANNELMAG FLOWMETERSFOR OPEN CHANNELS AND NON- FULL PIPES RTM- Expolink s.r.o., Prikop 8, 602

Page 2

10 Channel / Pipe ChannelMag Section

Page 3

11 ChannelMag Section 2 Installation 2.3.3 Important Note 2.4.1 CM2 Sensors Nominal CM2 Width Actual CM2 Width L S R H M

Page 4

12 ChannelMag Section 2 Installation The height “E” of the magnetic enhancement plates is custom made and normally

Page 5 - Table of Contents

13 ChannelMag Section 2 Installation 2.4.2 Installation of 2 x CM2 ChannelMag Sensors Adjust width before installation into channel 2

Page 6

14 ChannelMag Section 2 Installation The CM2/D is normally used with a FMX167 hydrostatic level transducer and installed as shown

Page 7 - Section I Introduccion

15 ChannelMag Section 2 Installation step should be cemented with an approach angle of not more than 15 degrees. The recess must extend over the f

Page 8

16 ChannelMag Section 2 Installation 2.4.5 PM2 Sensors in Non-Full Pipes The ChannelMag PM Series se

Page 9

17 ChannelMag Section 2 Installation 2.4.6 Installation of PM2 Sensors With Magnetic Enhancement Band Center spacer used for c

Page 10 - Section 2 Installation

18 Enhancement Plate Expander Mechanism The CM2 ChannelMag is equipped with a grounding plate, normally manufactured from AISI 316 stai

Page 11

19 ChannelMag Section 2 Installation 2.6 Cable Types Exciter Coils Electrodes Reference Coils Black to 4 Black to 24 Blac

Page 12

2 FOREWORD This instruction manual is designed to help you gain a thorough understanding of the operation of the equipment. ARKON

Page 13

20 ChannelMag Section 2 Installation 2.6.1 ChannelMag Junction Box Wiring Diagram

Page 14 - Approximate Weight

21 The Junction Box The cable ends and the junction box supplied for multi-Channel Mag systems are to NEMA 6 and IP68 for permanent submersi

Page 15

22 ChannelMag Section 2 Installation For multiple ChannelMag systems, the electrode and reference cable

Page 16

23 ChannelMag Section 4 Maintenance 4.1 Cleaning 4.2 Zero Span Checking 4.3 Effect of Moisture 4.4 Effect of a 4.5 Effect of One Sensor

Page 17

24 ChannelMag Section 4 Maintenance 4.6 Transmitter Fault 4.7 All Checks Good, But No Signal 4.8 Erratic Signa

Page 18

25 ChannelMag Section 5 Recommended Spares 5.1 Recommended Spares Since the ChannelMag sensor

Page 19

3 IMPORTANT – PLEASE READ The installation and operation of this product may put you at risk of serious injury or even death. Take whatever precau

Page 20

4 ChannelMag Table of ContentsSection 1 Introduction 1.1 Scope: ChannelMag CM2

Page 21

5 Table of Contents 4.8 Erratic Signal

Page 22

6 ChannelMag Section 1 Introduction The ChannelMag CM2 is suitable for open channels having diverse cross sectional shapes from 6” to 200 feet

Page 23

7 Chanel Mag Section I Introduccion The ChannelMag PM2 Series is suitable for full or partially full pipes from 20” to 120” (500 - 3000 mm).

Page 24 - Section 4 Maintenance

8 ChannelMag Section 1 Introduction Before installation, make sure the operating environments of the

Page 25

9 ChannelMag Section 2 Installation The ChannelMag is suitable for such media as water, raw sewage, slurries, algae laden river water, and similar

Comments to this Manuals

No comments